Lenel LNL-1200-S3 Series 3 Output Control Module (NEW)
Lenel LNL-1200-S3: Series 3 Output Control Module with 16 Form-C Relays
The Lenel LNL-1200-S3 Series 3 Output Control Module (OCM) communicates directly with the Intelligent System Controller by 2-wire or 4-wire RS-485. Each OCM is an individually addressed device and counts as a single device on all Intelligent System Controllers, making it a straightforward way to add 16 relay outputs to an OnGuard system.
Features and Benefits:
- 16 Relay Outputs: Sixteen Form-C relays rated 5 A at 30 VDC resistive, individually configurable for fail-safe or fail-secure operation.
- Full OnGuard Control: Relays respond to On, Off, and Pulse commands from OnGuard, and support elevator control for up to 128 floors.
- Simple Addressing: DIP switch addressing with on-board RS-485 termination jumpers, up to 16 OCMs per Intelligent System Controller.
- Drop-In Replacement: Suitable as a replacement for Series 1 and Series 2 LNL-1200 boards.
- Status at a Glance: LED indicators for communication, heartbeat, and relay status.
Technical Specifications:
- Inputs: 2 unsupervised inputs dedicated to cabinet tamper and UPS fault.
- Communications: RS-485 multidrop, 2-wire or 4-wire.
- Power: 12 to 24 VDC plus or minus 10%, 1100 mA maximum. 850 mA nominal at 12 VDC, 450 mA nominal at 24 VDC.
- Dimensions: 6 in W x 8 in L x 1 in H (152 x 203 x 25.4 mm), 14 oz (400 g) nominal.
- Environmental: Operating 0 to 70 C (32 to 158 F), storage -55 to 85 C, 0 to 95% RHNC.
- Certifications: FCC Part 15, CE, RoHS, UL 294, UL 2610.
Applications and Versatility: The LNL-1200-S3 provides relay expansion for OnGuard Intelligent System Controllers including the LNL-M3300, LNL-M2220, LNL-M4420, and X-Series boards, and is widely used for elevator floor control and general output switching.